Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Physiol ; 601(10): 1831-1850, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36929484

RESUMO

Because of the biophysical relation between muscle fibre diameter and the propagation velocity of action potentials along the muscle fibres, motor unit conduction velocity could be a non-invasive index of muscle fibre size in humans. However, the relation between motor unit conduction velocity and fibre size has been only assessed indirectly in animal models and in human patients with invasive intramuscular EMG recordings, or it has been mathematically derived from computer simulations. By combining advanced non-invasive techniques to record motor unit activity in vivo, i.e. high-density surface EMG, with the gold standard technique for muscle tissue sampling, i.e. muscle biopsy, here we investigated the relation between the conduction velocity of populations of motor units identified from the biceps brachii muscle, and muscle fibre diameter. We demonstrate the possibility of predicting muscle fibre diameter (R2  = 0.66) and cross-sectional area (R2  = 0.65) from conduction velocity estimates with low systematic bias (∼2% and ∼4% respectively) and a relatively low margin of individual error (∼8% and ∼16%, respectively). The proposed neuromuscular interface opens new perspectives in the use of high-density EMG as a non-invasive tool to estimate muscle fibre size without the need of surgical biopsy sampling. The non-invasive nature of high-density surface EMG for the assessment of muscle fibre size may be useful in studies monitoring child development, ageing, space and exercise physiology, although the applicability and validity of the proposed methodology need to be more directly assessed in these specific populations by future studies. KEY POINTS: Because of the biophysical relation between muscle fibre size and the propagation velocity of action potentials along the sarcolemma, motor unit conduction velocity could represent a potential non-invasive candidate for estimating muscle fibre size in vivo. This relation has been previously assessed in animal models and humans with invasive techniques, or it has been mathematically derived from simulations. By combining high-density surface EMG with muscle biopsy, here we explored the relation between the conduction velocity of populations of motor units and muscle fibre size in healthy individuals. Our results confirmed that motor unit conduction velocity can be considered as a novel biomarker of fibre size, which can be adopted to predict muscle fibre diameter and cross-sectional area with low systematic bias and margin of individual error. The proposed neuromuscular interface opens new perspectives in the use of high-density EMG as a non-invasive tool to estimate muscle fibre size without the need of surgical biopsy sampling.


Assuntos
Fibras Musculares Esqueléticas , Condução Nervosa , Criança , Humanos , Eletromiografia/métodos , Condução Nervosa/fisiologia , Fibras Musculares Esqueléticas/fisiologia , Músculo Esquelético/fisiologia , Potenciais de Ação/fisiologia
2.
Adv Clin Exp Med ; 30(2): 119-125, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33636056

RESUMO

The COVID-19 pandemic forced dental professionals to cope with an unexpected challenge and caused an abrupt cessation of conventional care practices. The high degree of contagiousness as well as the diffusion of the virus through the air and droplets via respiratory transmission placed dental professionals at top-level risk of contracting and spreading the disease. General recommendations were announced in different countries, including patient distancing, air ventilation, surface and instrument sanitization, and the wearing of suitable masks and shields. However, many dental treatments are performed using lasers, and some specific precautions must be added to conventional procedures to ensure the advantages of this technology to patients because of the particular tissue­matter interaction effects of laser wavelengths. Based on the literature, the authors evaluated all of using laser wavelengths to analyze the risk and the benefits of using lasers in daily dental practice, and to provide safety recommendations during pandemic. An unrestricted search of indexed databases was performed. Laser use effects were categorized into: 1) explosive processes that produce tissue ablation and aerosol formation; 2) thermal actions that create vaporization and smoke plume; 3) photobiomodulation of the cells; and 4) enhanced chemical activity. Knowledge of the device functions and choice of adequate parameters will reduce aerosol and plume formation, and the application of suction systems with high flow volume and good filtration close to the surgical site will avoid virus dissemination during laser use. In the categories that involve low energy, the beneficial effects of lasers are available and sometimes preferable during this pandemic because only conventional precautions are required. Lasers maintain the potential to add benefits to dental practice even in the COVID-19 era, but it is necessary to know how lasers work to utilize these advantages. The great potential of laser light, with undiscovered limits, may provide a different path to face the severe health challenges of this pandemic.


Assuntos
COVID-19/prevenção & controle , Assistência Odontológica/organização & administração , Controle de Infecções/normas , Terapia a Laser/normas , Gestão da Segurança/métodos , COVID-19/transmissão , Assistência Odontológica/métodos , Odontologia , Humanos , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Pandemias , Equipamento de Proteção Individual , Guias de Prática Clínica como Assunto , SARS-CoV-2
3.
IEEE Trans Biomed Eng ; 68(2): 526-534, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32746049

RESUMO

Blind source separation (BSS) algorithms, such as gradient convolution kernel compensation (gCKC), can efficiently and accurately decompose high-density surface electromyography (HD-sEMG) signals into constituent motor unit (MU) action potential trains. Once the separation matrix is blindly estimated on a signal interval, it is also possible to apply the same matrix to subsequent signal segments. Nonetheless, the trained separation matrices are sub-optimal in noisy conditions and require that incoming data undergo computationally expensive whitening. One unexplored alternative is to instead use the paired HD-sEMG signal and BSS output to train a model to predict MU activations within a supervised learning framework. A gated recurrent unit (GRU) network was trained to decompose both simulated and experimental unwhitened HD-sEMG signal using the output of the gCKC algorithm. The results on the experimental data were validated by comparison with the decomposition of concurrently recorded intramuscular EMG signals. The GRU network outperformed gCKC at low signal-to-noise ratios, proving superior performance in generalising to new data. Using 12 seconds of experimental data per recording, the GRU performed similarly to gCKC, at rates of agreement of 92.5% (84.5%-97.5%) and 94.9% (88.8%-100.0%) respectively for GRU and gCKC against matched intramuscular sources.


Assuntos
Aprendizado Profundo , Potenciais de Ação , Algoritmos , Eletromiografia , Músculo Esquelético , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
4.
Sci Rep ; 10(1): 5715, 2020 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-32235932

RESUMO

Crystallization of zeolite Li-A(BW) from kaolinite (Standard Porcelain by the IMERYS Minerals Ltd) through a conventional hydrothermal treatment is here achieved for the first time with no additives as reported in the literature. Moreover lower kaolin calcination temperatures and lower synthesis temperatures are tested and verified in this work. The synthesis process is rather simple as the reaction of kaolinite with alkali occurs very readily after calcination of at 650 °C. Metakaolin is mixed with calculated amount of aluminum hydroxide and lithium hydroxide and the experiment is performed at ambient pressure and 180 ± 0.1 °C. Li-A(BW) is characterized by powder X-ray diffraction, high temperature X-ray diffraction, scanning electron microscopy, inductively coupled plasma optical emission spectrometry, thermal analysis and infrared spectroscopy. Calculation of cell parameters (through Rietveld Refinement) and density, specific surface and pore size are also achieved. The amount of amorphous phase in the synthesis powders is estimated with quantitative phase analysis using the combined Rietveld and reference intensity ratio methods. The results become notably attractive in view of a possible industrial transfer of the synthesis protocol.

5.
World J Clin Cases ; 2(7): 293-6, 2014 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-25032206

RESUMO

Focal epithelial hyperplasia (FEH), or Heck's disease, is a rare disease of the oral mucosa; it is mostly found in children or young adults who are immunosuppressed and who live in regions with low socioeconomic status. It is characterized by asymptomatic papules on the oral mucosa, gingiva, tongue, and lips. Healing can be spontaneous, and treatment is indicated if there are aesthetic or functional complications. Human papillomavirus, especially genotypes 13 and 32, has been associated with FEH and is detected in the majority of lesions. Histopathologically, FEH is characterized by parakeratosis, epithelial hyperplasia, focal acanthosis, and fusion and horizontal outgrowth of epithelial ridges. A 37-year-old male patient was referred to the Department of Oral and Maxillofacial Sciences at the Sapienza University of Rome, complaining of numerous exophytic lesions in his mouth. He stated that the lesions were not painful but he had experienced occasional bleeding after incidental masticatory trauma. He had received no previous treatment for the oral lesions. His medical history revealed that he was human immuno-deficiency virus positive and was a smoker with numerous, asymptomatic oral papules clinically and histologically corresponding to FEH. The labial and buccal mucosa were especially affected by lesions. Surgical treatment was performed using a 532-nm potassium titanyl phosphate laser (SmartLite, Deka, Florence, Italy) in continuous mode with a 300 µm fiber and power of 1.4 W (power density 1980.22 W/cm(2)). After anesthesia without vasoconstrictors, the lesions were tractioned with sutures or an Allis clamp and then completely excised. The lesions were preserved in 10% formalin for histological examination, which confirmed the clinical diagnosis of FEH. In this case, the laser allowed excellent control of bleeding, without postoperative sutures, and optimal wound healing.

6.
Photomed Laser Surg ; 29(7): 447-52, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21235406

RESUMO

BACKGROUND: Bisphosphonate-related osteonecrosis of the jaw (BRONJ) is an adverse side effect associated with bisphosphonate (BP) therapy, especially when parenteral BP administration is used. Patients affected by BRONJ present wide areas of exposed necrotic bone, particularly after surgical oral procedures. The main symptom is pain that is poorly controlled by common analgesic drugs. Recently, many studies have pointed to the beneficial effect of low-level laser therapy (LLLT) in pain reduction for many pathological conditions. The purpose of this study is to investigate whether LLLT could be helpful in managing BRONJ by reducing the problems associated with this condition and the use of analgesic drugs. METHODS: Twelve patients affected by BRONJ were monitored at the Complex Operative Unit of Oral Pathology. Among these patients, only seven referred to pain in necrotic areas and were recruited for LLLT. Laser applications were performed with a double diode laser simultaneously emitting at two different wavelengths (λ = 650 nm and λ = 904-910 nm, spot size = 8 mm). All of the patients were irradiated with a fluence of 0.053 J/cm(2) for 15 min five times over a period of 2 weeks, in a non-contact mode, ∼1 mm from the pathologic area. The patient's maximum and minimum pain was recorded using a numeric rating scale (NRS) evaluation before and after the treatment. Statistical analysis was performed using the Kruskal-Wallis test. RESULTS: Six patients showed significant pain reduction, and only one patient indicated a worsening of the symptoms, which was probably related to a reinfection of the BRONJ site, which occurred during the study. A statistically significant difference (p < 0.05) was found between the NRS rates before and after the protocol. CONCLUSIONS: This pilot study suggests that LLLT may be a valid technique to support the treatment of BRONJ-related pain, even though the low number of cases in this study does not permit any conclusive consideration.


Assuntos
Conservadores da Densidade Óssea/efeitos adversos , Difosfonatos/efeitos adversos , Dor Facial/prevenção & controle , Doenças Maxilomandibulares/induzido quimicamente , Doenças Maxilomandibulares/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Osteonecrose/induzido quimicamente , Osteonecrose/radioterapia , Idoso , Idoso de 80 Anos ou mais , Dor Facial/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA